Why Venice has a tide gauge zero
Read one waterline with two rulers
In this model, one ruler can stand for the Punta della Salute tide gauge zero. The other begins at a different height.
Draw a canal viewed from the side. Add a thick horizontal mark for the water surface. Place one ruler so its zero is 6 cm below the mark. Place a second ruler so its zero is 4 cm below the same waterline. Assign one reader to report 6 cm and another to report 4 cm. Ask a third person to show where each measurement starts. In this model, both reports describe the same waterline.
Keep the mark still and slide only the second ruler down by 1 cm. Read both rulers again. Now hold the rulers still and move the waterline up by 1 cm using a strip of paper. In the first round, only one reading changes. In the second, both rise together. Have the next team write down which piece moved before it reads the numbers. It can also make tactile water and zero lines with string on cardboard so a teammate can follow the two movements by touch.
How much water covers a step?
Draw two steps on the bank. Suppose the water stands at 6 cm above zero A. Set the low step at 5 cm and the high one at 7 cm. The water covers the low step by 1 cm. The high one remains dry. Now switch to zero B, located 2 cm above zero A. Water level reads 4 cm, the low step sits at 3 cm and the high one at 5 cm. Subtract the low step’s height from the water level again. You still get a depth of 1 cm.
For a real flood report, the local ground height and the water level need the same reference before this subtraction works. Check the measurement unit too. A height of 0.06 m equals 6 cm. Write the original readings in a table before converting one of them. This gives the next reader a way to check the arithmetic if two teams get different answers.
Read alsoCuiabá’s Old Water Tank Museum: why does water find the same level?Find the measuring station
Find the Venetian lagoon on a map of Italy. Locate Punta della Salute near Punta della Dogana, at the entrance to the Grand Canal. Venice’s tide centre keeps records from a network of stations, including sites across the lagoon and a site at sea near the coast. Give each team a made-up station bulletin. One set comes from Station A; the other, from Station B. In each set, include two readings with different times. Before lining up the values, ask each reader to name the station, time, unit and starting reference. Then have a teammate point to the matching detail in the printed bulletin. Municipal Tide Centre, historical tide records.
Write a tide note that travels well
Draw a small card with spaces for level, datum, place and time. Fill it out for one practice reading. Give another unit the card and a separate note listing the step height. It has to decide whether the step is wet and show how it knows. For the second round, leave out one piece of information and ask the readers to say what they would request from the person who sent the note. End the meeting by writing the depth above the low step on a separate line. A reader should be able to tell which number came from the gauge and which came from subtraction.
Words in this guide
Punta della Salute tide gauge zero · The height reference the Venice tide centre uses to report local tide levels. Back to the term